Contact Form

Alcohol Tester

  • Product Name: Alcohol Tester

  • Specification: H3 High-Precision Alcohol Tester

  • Sensor: H3 High-Precision Alcohol Tester

  • Display: 0.96" TFT color display

  • Measurement Range: 0–400 mg/100ml

  • Detection Accuracy: ±6 mg/100ml

  • Product Dimensions: 42 × 90 × 11 mm

  • Battery Capacity: 300mAh

  • Ambient Temperature: 0–45°C

  • Ambient Humidity: 35–85%

  • Charging Method: Type-C DC 5V/1A

  • Housing Material: ABS engineering plastic

  • Voltage: 3.7 V

  • Weight: 0.22 kg

  • Warm-up Time: 10 seconds

  • Response Time: 1 second

  • Resolution: 240 × 240

  • Power Supply: Lithium battery

  • Measurement Object: Individuals who have consumed alcohol

Description

Intelligent high precision
Specifically designed to detect overnight alcohol
Compact and simple, easy to carry

  • Pressure sensing

  • Electrochemical sensor

  • Results in seconds

  • Stable performance

  • Three-color display

  • Quick screening

  • Dual testing modes

  • Long battery life

4.jpg

Dual testing modes to meet different needs

  • Precise Mode – Requires a mouthpiece for more accurate detection

  • Quick Screening Mode – No mouthpiece required, suitable for screening multiple people

  1. Precise Measurement Mode

  2. Quick Screening Mode

5.jpg

High-precision electrochemical sensor for more accurate measurement
Identifies alcohol more precisely than traditional semiconductor sensors, offering greater sensitivity, more stable transmission, and stronger anti-interference capability.

6.jpg

3-second reading with three-color indicator
Three colors represent three post-drinking states – results at a glance.

  • 0.00 mg/100ml
    Green light on
    Safe

  • 20 mg/100ml
    Yellow light on
    Drunk Driving (DUI)

  • 80 mg/100ml
    Red light on
    Drunken Driving (DWI)

7.jpg

500 tests per charge
USB portable charging – 30 minutes of charging supports up to 500 tests.

8.jpg

Superior quality in every detail
Comprehensive attention to detail – quality at its finest.

  • 5 mouthpieces included – replaceable / washable for repeated use

  • 0.96" TFT color display – full-color, clear readings

  • ABS engineering plastic housing – sturdy and wear-resistant

Usable in multiple countries: China / United States / European countries / Japan

  • Chinese standard unit: mg/100mL

  • European standard unit: g/L

  • American standard unit: %BAC

  • Japanese standard unit: mg/L

9.jpg

Instructions for Use:

  1. Press and hold the [Power On button] for more than 2 seconds to turn on the device. Briefly press the [Power On button] to enter the blowing interface.

  2. Take a deep breath, then blow continuously into the mouthpiece for 3 seconds. When blowing starts, a vibration alert will be triggered. The vibration will stop after 3 seconds of blowing. If the blowing time is less than 3 seconds or is interrupted, the device will prompt "Blowing interrupted" and re-enter the blowing phase.

  3. After a single-person test mode is completed, the result will be displayed on the screen. The device will automatically shut down after 30 seconds of inactivity.

  4. After a multi-person test mode is completed, the result will be displayed on the screen. Briefly press the [Power On button] to return to the main interface and prepare for the next test.

10.jpg

Precautions:

  1. Please wait at least 20 minutes after drinking before testing, as it takes approximately 20 minutes for alcohol to be absorbed from the digestive system into the bloodstream. Testing immediately after drinking will only reflect the alcohol concentration in the mouth at that time, not the blood alcohol concentration. Test results will show dynamic changes as the alcohol is absorbed into the body.

  2. Please use the device with the mouthpiece.

  3. During testing, do not block the air outlet on the right side of the display screen with your hand, as this may affect testing accuracy.

  4. Do not wipe the product directly with chemicals or corrosive solutions. Avoid allowing liquid to enter the blow hole.

  5. This product will not function properly in the presence of high concentrations of interfering gases.

  6. Testing under low battery conditions may result in deviations between the test value and the actual value.


FAQs

REQUEST A QUOTE

REQUEST A QUOTE