Product Name: Alcohol Tester
Specification: English Version
Sensor: High-sensitivity semiconductor alcohol sensor
Test Range: 0.00–0.19% BAC (0.0–1.9 g/L)
Accuracy: -0.01 to +0.02% BAC (at 0.05% BAC alarm point)
Power Supply: 2 x AAA alkaline batteries
Warm-up Time: 10 seconds
Blowing Time: Within 10 seconds (generally 3–5 seconds recommended)
Response Time: <5 seconds
Shutdown Time: 10 seconds after result is displayed
Product Dimensions: 118 × 70 × 28 mm
Operating Environment: 5°C – 40°C
Weight: 0.043 kg
Voltage: 3 V
Measurement Object: Individuals who have consumed alcohol
Resolution: 0.001
Description
Alcohol Tester
Uses a high-sensitivity semiconductor alcohol sensor – accurate data and fast response.

LED backlit digital display
Easier observation at night

Battery Installation Instructions
Open the back cover of the tester, install two AAA batteries, close the back cover, and the device is ready for testing.
AAA battery compartment
Battery cover

Detailed Explanation of Drunk Driving
According to a report by the World Health Organization:
Drunk Driving (DUI):
When a driver's blood alcohol concentration (BAC) is greater than or equal to 20mg/100ml but less than 80mg/100ml, the chance of being involved in a traffic accident is 2.5 times higher than when there is no alcohol in the blood.
Drunken Driving (DWI):
When BAC exceeds 80mg/100ml, the chance of a traffic accident is 4.7 times higher than when there is no alcohol in the blood.
Even in a state of low-level alcohol consumption, the risk of a traffic accident is approximately twice that of a sober state.
Over-limit alarm prompt – automatically shuts off after testing
When the detected alcohol concentration exceeds the limit, an alarm sound is emitted. The device automatically shuts down 10 seconds after the value is displayed.
Turn on the alcohol tester. It will enter the "Blow" state as shown in the figure for 10 seconds. Blow with moderate force for 3–5 seconds!
If the alcohol concentration reaches the drunken driving range, a prompt tone will sound. The device will automatically shut down 10 seconds after the value is displayed.

Currently known foods and medications that may cause a positive breathalyzer result (false drunk driving reading)
| Foods | Egg yolk pastry, tiramisu, fermented tofu, papaya water, cooking wine, alcohol-filled candies. Additionally, fruits with high sugar content, if stored improperly, can also produce alcohol, such as apples, pears, etc. |
| Oral & Topical Medications | Huoxiang Zhengqi Liquid, Zhenggu Water (Zhenggu Liquid), Di Shui (Ten Drops), Xiaokechuan Syrup, etc. |
| Injectable Medications | Hydrocortisone, Nimodipine, Xueshuantong (Panax Notoginseng Saponins for Injection), Nicergoline, Docetaxel Injection, etc. |
| Daily Necessities | Mouthwash containing ethanol, etc. |
Drunk driving is very dangerous!
Keep an alcohol tester on hand at all times
To remind yourself at critical moments
Take responsibility for yourself and for others.

When the tester is first taken out of the packaging or has not been used for a long time, oxidation may occur on the sensor surface. Users need to warm up the product several times before performing an alcohol test.
| Behavior Type | Breath Alcohol Concentration (BrAC) | Blood Alcohol Concentration (BAC) |
| Drunk driving | 0.10 mg/L | 0.02% BAC |
| Drunken driving | 0.40 mg/L | 0.08% BAC |
Alcohol Concentration Conversion Table
| No. | Unit | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
| BAC – Blood Alcohol Concentration | mg/100ml | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 | 110 | 120 |
| % | 0.01 | 0.02 | 0.03 | 0.04 | 0.05 | 0.06 | 0.07 | 0.08 | 0.09 | 0.10 | 0.11 | 0.12 | |
| ‰ | 0.1 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | 0.8 | 0.9 | 1.0 | 1.1 | 1.2 | |
| g/l | 0.1 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | 0.8 | 0.9 | 1.0 | 1.1 | 1.2 |
Commonly used units in different countries:
mg/100ml – China
mg/l BrAC – Japan
% BAC – United States
g/l – Europe
0.05% BAC means 0.05 grams of alcohol per 100 milliliters of blood.
Red indicates the display unit of this product.
Yellow indicates the display unit of this product.
Troubleshooting
| Fault Phenomenon | Possible Causes of Failure | Solutions |
Unable to power on | Batteries not installed properly | Install batteries correctly according to the battery polarity markings |
Battery severely depleted | Replace with new alkaline batteries | |
Circuit malfunction | Contact after-sales service for repair | |
No response when blowing | Not fully warmed up | Warm up the device several more times |
Circuit malfunction | Contact after-sales service for repair | |
No result displayed after blowing | Residual gas inside the product | Re-warm up the product |
Blowing not performed within the specified time | Blow within the "BLOW" time period | |
Residual gas inside the product | Warm up the product several more times | |
Result displayed without blowing | Blowing not performed within the specified time | Blow within the "BLOW" time period |
Tested immediately after drinking alcohol | Wait 20 minutes after drinking before testing | |
Different results from several tests | Inconsistent blowing time | It is recommended to exhale deeply for 3–5 seconds |
Instructions for Use:
1. Begin the test 20 minutes after drinking. To use the alcohol tester, press and hold the power button for 1 second. After a "beep" sound, the LCD screen of the tester will turn on.

2. Enter warm-up mode. "Warmup" appears on the display. In warm-up mode, a countdown from 10 to 00 will begin.

3. After "Warmup" ends, the "Blow" icon appears on the display. In this mode, a countdown from 10 to 00 begins. During this period, place your mouth around the mouthpiece and blow with moderate force for 3–5 seconds.

4. If the alcohol concentration is in the range of 0.02% BAC (0.2 g/L) to 0.05% BAC (0.5 g/L), the "Caution" warning icon will appear.
If the alcohol concentration is ≥ 0.05% BAC (0.5 g/L), the "Danger" warning icon will appear, accompanied by an audible alert tone.

5. The device automatically shuts down 10 seconds after the blood alcohol concentration is displayed. To achieve more accurate test results, it is recommended that users repeat the test 2 to 3 times.

Drunk alarm function: If the alcohol concentration is ≥ 0.5, the "Danger" icon will be displayed and a "beep beep" warning sound will be emitted.

FAQs
A: We focus on 12 core industrial product categories, mainly including:
Safety protection equipment: metal detectors, security scanners, security checkpoint platforms, safety bollards
Storage solutions: safes, security trays, anti-theft storage cabinets
Warning signs: various warning tapes, safety sign boards
Smart industrial equipment: IoT sensors, smart monitoring devices
Personal protective equipment (PPE): safety helmets, protective clothing, protective gloves, etc.
Firefighting equipment: fire extinguishers, fire hydrants, emergency lighting
Tools and hardware: industrial-grade manual/power tools
Electrical components: circuit breakers, cables, distribution boxes
Logistics packaging: pallets, returnable containers, packaging materials
Cleaning supplies: industrial cleaners, dust removal equipment
Office supplies: office furniture, stationery consumables
Other industrial consumables
All products comply with international quality standards (ISO9001, CE certification, etc.).
A: We support combined orders across multiple product categories to lower the minimum order threshold for individual items. For further inquiries, please contact our sales team for accurate quotations.
A: Yes, we offer OEM/ODM customization services:
Logo customization: Print your brand logo on the products.
Specification adjustments: Dimensions, colors, and materials can be modified according to your requirements.
Packaging design: Customized outer packaging boxes and instruction manuals.
Function development: Tailored functional features for specific application scenarios.
A: We implement full-process quality control:
Supplier screening: We partner only with factories that are ISO9001 certified.
Incoming material inspection: 100% random sampling inspection is conducted before raw materials are accepted into storage.
Production process monitoring: Real‑time quality checks are performed at critical production stages.
Outgoing inspection: Random sampling tests are carried out on each batch before shipment.
Third‑party certification: We regularly commission international testing agencies such as SGS and TÜV for independent verification.
Warranty commitment: All products come with a 12‑ to 24‑month warranty period.
Should any quality issues arise, we promise to:
Offer free return or exchange within 7 days.
Bear the round‑trip shipping costs.
Provide technical support to resolve any usage problems.
A: Our quotations are typically provided on either FOB (Free on Board) or CIF (Cost, Insurance and Freight) terms:
FOB price includes:
Product cost
Domestic transportation to the port of shipment
Export customs clearance fees
Does not include: international freight charges and import duties.
CIF price includes:
All FOB items
International ocean/air freight
Marine/aviation insurance
Does not include: destination port clearance fees and inland transportation costs.
Additional charges that may apply:
Customization fees (for logo/specification modifications)
Special packaging fees (wooden crates, moisture-proof packaging, etc.)
Rush order fees (for expedited delivery)
We clearly list all cost breakdowns in our quotation, with no hidden charges.
A: We support a variety of international payment methods, including PayPal, Letter of Credit (L/C), Alibaba Trade Assurance, and RMB (CNY) bank transfers.
Payment Terms:
Sample orders: 100% prepayment.
Regular orders: 30% deposit + 70% balance payment before shipment.
Long-term cooperative clients: Credit terms (Net 30/60/90) may be applied upon request